Wired Alarm Host 4+2 Zone PA-728EX
4 zone inputs, 2 partitions, 256 events buffered, 1 pgm output, 950ma switching power supply, Supervised bell output, auxiliary output and telephone line, 2-wire smoke detector input option (input 3), Serial or parallel wiring for zone doubling connections, Master code lock: Cannot change or delete the master code or user code 01, Supports pager reporting.
Programmable output PGM, maximum 5 keyboard, high-speed communication format. 48 user password + one main user password + 1 installer password
3 emergency keys keyboard
Anti-false alarm suite: intelligent Standoff, automatic bypass Standoff, audible exit delay, programmable alarm transmission delay and just closed 〃 〃 report
Alarm output relay (728 no)
Conventional deployment, rear guard, double rear guard, forced to withdraw from deployment, the deployment of conventional one-click, one-touch rear guard, one-touch deployment and then quit automatically deployed on time, keys switch deployment, PS1 bedside remote control keyboard deployment
Programmable Output PGM (728 has one output, there are two other models), when one has specified event or state occurs, the PGM output can be used to trigger the blinking light or door switch or other control, the maximum output 50mA, PGM output can be the basis of 1000 more than the state of the trigger parameters, example: PGM programming so 〔1〕 and 〔2〕 two keys are pressed at the same time be able to switch automatically car door
maximum 5 keyboard
telephone lines to monitor
high-speed communication format: 12 kinds of formats including Ademco Contact ID (report all code), Ademco Contact ID (programmable codes), 4 +2, personal communications,
can be divided into two subsystems
256 event memory
Stand-automatically with each trigger tamper show
48 User Password + one main user password + 1 installer password
upload and download function
Battery Charger: 360mA with battery test
Auxiliary power output: 400 mA (748 to 1000mA), with automatic reset electronic fuses, current limiting 1A
alarm output: 1A, with automatic reset electronic fuses, current limiting 3 A
Ac AC Input: AC16.5V, 3A ,50-60HZ
PGM programmable output: Earth () normally closed or normally open, 50mA maximum current
Serial Port data output: (1200, 1, N) required to reprovision module